● ISO 9001:2015 · ANSI/ESD S20.20-2021 · ERAI Member · GIDEP · Woman-Owned Small Business 760.724.2800 · 855.RH.HAS.IT · info@rhelectronics.com
Clarostat Sensors and Controls  · Electronic Components

JA1N100P501UA

Resistor, Variable, Nonwire Wound,

Part NumberJA1N100P501UA
ManufacturerClarostat Sensors and Controls
AvailabilityAvailable to order — request a quote

Specifications

Federal Item NameRESISTOR,VARIABLE,NONWIRE WOUND,
Federal Supply Class5905 — Resistors
Maximum Starting Torque6.00 INCH-OUNCES
Maximum Running Torque6.00 INCH-OUNCES
Actuator TypeSINGLE SHAFT
Effective Electrical Rotation In D312.0 NOMINAL
Terminal Type And Quantity3 TAB, SOLDER LUG
Ambient Temp In Deg Celsius Per Se70.0 SINGLE SECTION
Power Dissipation Rating Per Secti2.25 FREE AIR SINGLE SECTION
Resistance Tolerance Per Section I-10.0 TO 10.0 SINGLE SECTION
Resistance Temp Characteristic Ran+0.0 TO 5.5 -55 DEG CELSIUS SINGLE SECTION AND +0.0 TO 3.0 -25 DEG CELSIUS SINGLE SECTION AND +0.0 TO 1.5 0 DEG CELSIUS
Mechanical Backlash In Deg Angular1.5
Body StyleCYLINDRICAL BUSHING MOUNTED
Review your list (0) →
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant

Frequently asked

Is JA1N100P501UA available?
We can source JA1N100P501UA even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is JA1N100P501UA by Clarostat Sensors and Controls obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If JA1N100P501UA has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like JA1N100P501UA?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for JA1N100P501UA?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.