IULHK1119-1REC4-30372-21

Circuit Breaker

Part NumberIULHK1119-1REC4-30372-21
ManufacturerSensata Technologies Maryland
AvailabilityAvailable to order — request a quote

Specifications

Federal Item NameCIRCUIT BREAKER
Federal Supply Class5925 — Circuit Breakers
Maximum Continuous Load Current Ra35.0 AMPERES AC THIRD LOCATION
Frequency In Hertz60.0 ALL LOCATIONS
Trip Delay Time In Seconds Per Rat63.000 NOMINAL AT 125 PCT THIRD LOCATION
Body Length3.015 INCHES NOMINAL
Trip Release MethodTHERMAL-MAGNETIC ALL LOCATIONS
Reset MethodMANUAL
Trip Release Ambient Temp Rating70.0 CELSIUS NOMINAL ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Nominal Thread Size0.138 INCHES
Ultimate Trip Rating Of Continuous125.0 ALL LOCATIONS
Vendor Part Numbers99002A8046-21
ESD/EMICode A — ESD/EMI sensitive item
Review your list (0) →
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant

Frequently asked

Is IULHK1119-1REC4-30372-21 available?
We can source IULHK1119-1REC4-30372-21 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is IULHK1119-1REC4-30372-21 by Sensata Technologies Maryland obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If IULHK1119-1REC4-30372-21 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like IULHK1119-1REC4-30372-21?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for IULHK1119-1REC4-30372-21?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.