● ISO 9001:2015 · ANSI/ESD S20.20-2021 · ERAI Member · GIDEP · Woman-Owned Small Business 760.724.2800 · 855.RH.HAS.IT · info@rhelectronics.com
Home / Catalog / Lockheed Martin / C7653-1
Lockheed Martin  · Electronic Components

C7653-1

Filter, Low Pass

Part NumberC7653-1
ManufacturerLockheed Martin
AvailabilityAvailable to order — request a quote

Specifications

Federal Item NameFILTER,LOW PASS
Federal Supply Class5915 — Filters and Networks
Voltage Standing Wave Ratio Per Fu1.35 BLANK LOCATION NOT OTHERWISE SPECIFIED
Output Terminal IdentificationR-MALE
Average Power Rating Per Function100.0 WATTS BLANK LOCATION NOT OTHERWISE SPECIFIED
Input Terminal IdentificationR-FEMALE
Output Terminal Manufacturer Code12598
Mounting Facility Type And Quantit1 CLAMP LOCATION NOT OTHERWISE SPECIFIED
Overall Length2.438 INCHES NOMINAL2.438 INCHES NOMINAL
Discrimination At Specified Freque1.0 MAXIMUM BLANK AND 60.0 MINIMUM BLANK FIRST FUNCTION
Unpackaged Unit Weight4.000 OUNCES NOMINAL
Insertion Loss At Reference Freque0.35 BLANK LOCATION NOT OTHERWISE SPECIFIED
Style DesignatorROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
Vendor Part Numbers4676-1, F-30-12.4R
Review your list (0) →
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant

Frequently asked

Is C7653-1 available?
We can source C7653-1 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is C7653-1 by Lockheed Martin obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If C7653-1 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like C7653-1?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for C7653-1?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.