Circuit Breaker

Part NumberAPL-111-1REC4-42-103-MA
ManufacturerSensata Technologies Maryland
AvailabilityAvailable to order — request a quote

Specifications

Federal Item NameCIRCUIT BREAKER
Federal Supply Class5925 — Circuit Breakers
Maximum Continuous Load Current Ra10.0 AMPERES AC ALL LOCATIONS
Terminal Type And Quantity6 THREADED STUD
MaterialPLASTIC CASE
Maximum Interrupting Capacity Curr1500.0 AC ALL LOCATIONS
Trip Release MethodMAGNETIC ALL LOCATIONS
Main Contact Tripping Mechanism TyTRIP FREE
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Trip Delay Time In Seconds Per Rat2.000 MINIMUM AT 200 PCT AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Frequency In Hertz400.0 ALL LOCATIONS
Pole Quantity3
Center To Center Distance Between0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
ESD/EMICode A — ESD/EMI sensitive item
Review your list (0) →
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant

Frequently asked

Is APL-111-1REC4-42-103-MA available?
We can source APL-111-1REC4-42-103-MA even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is APL-111-1REC4-42-103-MA by Sensata Technologies Maryland obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If APL-111-1REC4-42-103-MA has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like APL-111-1REC4-42-103-MA?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for APL-111-1REC4-42-103-MA?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.