● ISO 9001:2015 · ANSI/ESD S20.20-2021 · ERAI Member · GIDEP · Woman-Owned Small Business 760.724.2800 · 855.RH.HAS.IT · info@rhelectronics.com
Keysight Technologies Inc.  · Electronic Components

8120-0689

Cable, Special Purpose, Electrical

Part Number8120-0689
ManufacturerKeysight Technologies Inc.
AvailabilityAvailable to order — request a quote

Specifications

Federal Item NameCABLE,SPECIAL PURPOSE,ELECTRICAL
Federal Supply Class6145 — Wire and Cable, Electrical
Cross Section Outside Diameter0.370 INCHES NOMINAL
Round Conductor Size28 AWG ALL CONDUCTORS
Voltage Rating300.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
Strand Awg Size Per Conductor36 ALL CONDUCTORS
Surface TreatmentTIN CORE CONDUCTOR ALL CONDUCTORS
Conductor Arrangement And Quantity9 TRIPLES AND 1 TWISTED PAIR
MaterialPLASTIC POLYVINYL CHLORIDE (PVC) FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
Cross Sectional Shape StyleROUND
Surface Treatment Document And ClaASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
Material Document And ClassificatiQQ-W-343,SOFT FED SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
Conductor FormSTRANDED ALL CONDUCTORS
Review your list (0) →
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant

Frequently asked

Is 8120-0689 available?
We can source 8120-0689 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 8120-0689 by Keysight Technologies Inc. obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 8120-0689 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 8120-0689?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 8120-0689?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.