Artted · Electronic Components
7882
Coil, Radio Frequency
Part Number7882
ManufacturerArtted
AvailabilityAvailable to order — request a quote
Specifications
NSN5950-01-015-3610 (NSN)
Federal Item NameCOIL,RADIO FREQUENCY
Federal Supply Class5950 — Coils and Transformers
Terminal Type And Quantity2 PIN
Quality Factor90 MINIMUM SINGLE COMPONENT SINGLE WINDING
Mounting Tab Width0.060 INCHES NOMINAL
Mounting MethodTAB SINGLE GROUP
Inductance Rating3.43 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
Body Width0.453 INCHES NOMINAL
Inclosure TypeFULLY INCLOSED
Reliability IndicatorNOT ESTABLISHED
Body Height5.000 INCHES NOMINAL
Body Length0.453 INCHES NOMINAL
Coil Form TypeSOLID SINGLE COMPONENT
Overall Height2.312 INCHES NOMINAL
Individual Section Quantity1
ColorBLACK SINGLE INDICATOR BACKGROUND
Overall Width1.188 INCHES NOMINAL
Contact Voltage Rating In Volts28.0 DC AT SEA LEVEL
Actuator TypeTHUMBWHEEL SINGLE ACTUATOR
Terminal TypePRINTED CIRCUIT
Contact Load Current Rating3.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL
Switch Actuator Indexing Position10 SINGLE ACTUATOR
Readout Indicator Marking0,1,2,3,4,5,6,7,8,9 SINGLE SECTION
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Frequently asked
Is 7882 available?
We can source 7882 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 7882 by Artted obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 7882 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 7882?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 7882?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.