● ISO 9001:2015 · ANSI/ESD S20.20-2021 · ERAI Member · GIDEP · Woman-Owned Small Business 760.724.2800 · 855.RH.HAS.IT · info@rhelectronics.com
Sensata Technologies  · Electronic Components

7235-1-80

Circuit Breaker

Part Number7235-1-80
ManufacturerSensata Technologies
AvailabilityAvailable to order — request a quote

Specifications

Federal Item NameCIRCUIT BREAKER
Federal Supply Class5925 — Circuit Breakers
Trip Release Ambient Temp Rating25.0 CELSIUS NOMINAL SINGLE LOCATION
Inclosure Protection Type For WhicFUNGUS RESISTANT
Maximum Continuous Load Current Ra80.0 AMPERES AC AND 80.0 AMPERES DC SINGLE LOCATION
MaterialPLASTIC CASE
Frequency In Hertz60.0 SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Ultimate Trip Rating Of Continuous138.0 SINGLE LOCATION
Operating Voltage Type And Rating115.0 AC AND 28.0 DC SINGLE LOCATION
Trip Delay Time In Seconds Per Rat10.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT SINGLE LOCATION
Internal Trip Release ConfiguratioSERIES TRIP SINGLE LOCATION
Center To Center Distance Between2.625 INCHES NOMINAL
Vendor Part Numbers11069754
Review your list (0) →
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant

Frequently asked

Is 7235-1-80 available?
We can source 7235-1-80 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 7235-1-80 by Sensata Technologies obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 7235-1-80 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 7235-1-80?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 7235-1-80?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.