● ISO 9001:2015 · ANSI/ESD S20.20-2021 · ERAI Member · GIDEP · Woman-Owned Small Business 760.724.2800 · 855.RH.HAS.IT · info@rhelectronics.com
Sigma Instruments Inc. Fisher-Pierce Div  · Electronic Components

70R4T-110DC

Relay, Electromagnetic

Part Number70R4T-110DC
ManufacturerSigma Instruments Inc. Fisher-Pierce Div
AvailabilityAvailable to order — request a quote

Specifications

Federal Item NameRELAY,ELECTROMAGNETIC
Federal Supply Class5945 — Relays and Solenoids
Main Contact Maximum Voltage Ratin115.0 DC
Nonpile Up Main Contact Arrangemen4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Precious Material And LocationCONTACTS GOLD AND CONTACTS PLATINUM AND CONTACTS SILVER
Main Contact Load Current Rating A2.0 AMPERES DC RESISTIVE LOAD
Cubic Measure1.198 CUBIC INCHES
Storage TypeGENERAL PURPOSE WAREHOUSE
Mounting Facility Type And Quantit1 TERMINAL SINGLE MOUNTING FACILITY
Precious MaterialGOLD AND PLATINUM AND SILVER
Winding Dc Resistance Rating15.0 OHMS NOMINAL SINGLE WINDING
Terminal Type And Quantity14 TAB, SOLDER LUG ALL FUNCTIONS
Winding Quantity1
Vendor Part NumbersAZ421-035-10L
Review your list (0) →
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant

Frequently asked

Is 70R4T-110DC available?
We can source 70R4T-110DC even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 70R4T-110DC by Sigma Instruments Inc. Fisher-Pierce Div obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 70R4T-110DC has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 70R4T-110DC?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 70R4T-110DC?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.