General Dynamics Mission Systems · Electronic Components
40-904006-4711
Capacitor, Fixed, Glass Dielectric
Part Number40-904006-4711
ManufacturerGeneral Dynamics Mission Systems
AvailabilityAvailable to order — request a quote
Specifications
NSN5910-00-999-2042 (NSN)
Federal Item NameCAPACITOR,FIXED,GLASS DIELECTRIC
Federal Supply Class5910 — Capacitors
Temp Coefficient Of Capacitance Pe140.0 SINGLE SECTION
Terminal Diameter0.020 INCHES NOMINAL
Body Height0.110 INCHES MINIMUM AND 0.120 INCHES MAXIMUM
Schematic Diagram DesignatorNO COMMON OR GROUNDED ELECTRODE(S)
Center To Center Distance Between0.180 INCHES MINIMUM AND 0.220 INCHES MAXIMUM
Capacitance Value Per Section470.000 PICOFARADS SINGLE SECTION
Nonderated Continuous Voltage Rati300.0 DC SINGLE SECTION
Tolerance Range Per Section-1.00 TO 1.00 PERCENT SINGLE SECTION
Tolerance Of Temp Coefficient Per-25.0 TO 25.0 SINGLE SECTION
Insulation Resistance At Maximum O10000.0 MEGOHMS
Body Length0.295 INCHES MINIMUM AND 0.305 INCHES MAXIMUM
Cancelled NSN5910-00-941-4860 (cancelled)
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Frequently asked
Is 40-904006-4711 available?
We can source 40-904006-4711 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 40-904006-4711 by General Dynamics Mission Systems obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 40-904006-4711 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 40-904006-4711?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 40-904006-4711?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.