● ISO 9001:2015 · ANSI/ESD S20.20-2021 · ERAI Member · GIDEP · Woman-Owned Small Business 760.724.2800 · 855.RH.HAS.IT · info@rhelectronics.com
Electro Impulse Laboratory  · Electronic Components

34546

Waveguide Assembly

Part Number34546
ManufacturerElectro Impulse Laboratory
AvailabilityAvailable to order — request a quote

Specifications

Federal Item NameWAVEGUIDE ASSEMBLY
Federal Supply Class5985 — Antennas and Waveguides
Waveguide Outside Width1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM
Voltage Standing Wave Ratio1.05
Tubing Wall Construction StyleSEAMLESS SINGLE TUBING SEGMENT
Flange Depth0.423 INCHES MINIMUM AND 0.453 INCHES MAXIMUM FIRST FLANGE
Flange Inside Height0.628 INCHES MINIMUM AND 0.631 INCHES MAXIMUM FIRST FLANGE
Waveguide Inside Height0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM
Waveguide Longer Offset Distance3.500 INCHES NOMINAL
MaterialCOPPER ALLOY SINGLE TUBING SEGMENT
Cross Sectional Shape StyleINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
Flange Connecting Hole Diameter0.169 INCHES MINIMUM AND 0.172 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES
Flange Outside Width1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM FIRST FLANGE
Vendor Part NumbersR12-960
Review your list (0) →
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant

Frequently asked

Is 34546 available?
We can source 34546 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 34546 by Electro Impulse Laboratory obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 34546 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 34546?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 34546?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.