● ISO 9001:2015 · ANSI/ESD S20.20-2021 · ERAI Member · GIDEP · Woman-Owned Small Business 760.724.2800 · 855.RH.HAS.IT · info@rhelectronics.com
National Weather Service Nexrad Radar Operations Center  · Electronic Components

2320144-301

Cable Assembly, Special Purpose, E

Part Number2320144-301
ManufacturerNational Weather Service Nexrad Radar Operations Center
AvailabilityAvailable to order — request a quote

Specifications

Federal Item NameCABLE ASSEMBLY,SPECIAL PURPOSE,E
Federal Supply Class6150 — Electric Power and Distribution Equipment
Cable Assembly Overall Length89.000 INCHES NOMINAL
Terminal Commercial And Government81349 BOTH ENDS ALL CONDUCTORS
Binding MethodSLEEVE AND TAPE LACED AND WIRE BOUND
Surface TreatmentTIN THIRD POSITION SHIELD BRAID METALLIC CABLE
Branch Quantity3
MaterialCOPPER THIRD POSITION SHIELD BRAID METALLIC CABLE
Termination TypeCONNECTOR PLUG FIRST END ALL CONDUCTORS
Usage DesignPOWER
Terminal Manufacturer IdentifyingM24308/4-1 SECOND END ALL CONDUCTORS
Conductor Quantity8
ESD/EMICode A — ESD/EMI sensitive item
Review your list (0) →
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant

Frequently asked

Is 2320144-301 available?
We can source 2320144-301 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 2320144-301 by National Weather Service Nexrad Radar Operations Center obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 2320144-301 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 2320144-301?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 2320144-301?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.