Keysight Technologies Inc. · Electronic Components
2100-0342
Resistor, Variable, Wire Wound, Non
Part Number2100-0342
ManufacturerKeysight Technologies Inc.
AvailabilityAvailable to order — request a quote
Specifications
NSN5905-00-930-8643 (NSN)
Federal Item NameRESISTOR,VARIABLE,WIRE WOUND,NON
Federal Supply Class5905 — Resistors
Undercut Diameter0.187 INCHES NOMINAL
Electrical Resistance Per Section10.0 KILOHMS 1ST SECTION AND 800.0 OHMS 2ND SECTION
Ambient Temp In Deg Celsius Per Se85.0 ALL SECTIONS
Body Diameter1.266 INCHES NOMINAL
Terminal Type And Quantity6 TAB, SOLDER LUG
Actuator Travel Control FeatureSTOPS
Terminal LocationRADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE LOCATION NOT OTHERWISE SPECIFIED
Resistance Tolerance Per Section I-10.0 TO 10.0 ALL SECTIONS
Power Dissipation Rating Per Secti2.0 FREE AIR ALL SECTIONS
Device Design TypeAT 9:00 OCLOCK LOCATION NOT OTHERWISE SPECIFIED
Rotary Actuator Travel In Angular300.0 NOMINAL
Cancelled NSN5905-00-761-8881 (cancelled)
ESD/EMICode B — ESD/EMI sensitive item
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Frequently asked
Is 2100-0342 available?
We can source 2100-0342 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 2100-0342 by Keysight Technologies Inc. obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 2100-0342 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 2100-0342?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 2100-0342?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.