● ISO 9001:2015 · ANSI/ESD S20.20-2021 · ERAI Member · GIDEP · Woman-Owned Small Business 760.724.2800 · 855.RH.HAS.IT · info@rhelectronics.com
Home / Catalog / Fluke Corp. / 182410
Fluke Corp.  · Electronic Components

182410

Resistor, Variable, Wire Wound, Non

Part Number182410
ManufacturerFluke Corp.
AvailabilityAvailable to order — request a quote

Specifications

Federal Item NameRESISTOR,VARIABLE,WIRE WOUND,NON
Federal Supply Class5905 — Resistors
Ambient Temp In Deg Celsius Per Se105.0 SINGLE SECTION
Effective Electrical Rotation In D240.0 NOMINAL
Mounting MethodTERMINAL
Rotary Actuator Travel In Angular270.0 NOMINAL
Electrical Resistance Per Section2.0 OHMS SINGLE SECTION
Resistance Tolerance Per Section I-10.0 TO 10.0 SINGLE SECTION
Power Dissipation Rating Per Secti2.0 FREE AIR SINGLE SECTION
Actuator Travel Control FeatureSTOPS
Terminal LocationFRONT END LOCATION NOT OTHERWISE SPECIFIED
Terminal Type And Quantity3 TAB, SOLDER LUG
Actuator TypeFLUSH DRIVE WITH SLOT-HOLE
ESD/EMICode B — ESD/EMI sensitive item
RohscompliantYES
Sensor MountingPanel Mount
Hazardousfalse
RohsphthalatescompliantYES
Product Range1800 Series
IscanonicalY
Switching Current Dc Resistive-
Contact ConfigurationSPDT
Operating Pressure Min2 Inch-H2O
Review your list (0) →
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant

Frequently asked

Is 182410 available?
We can source 182410 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 182410 by Fluke Corp. obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 182410 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 182410?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 182410?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.