L3Harris Technologies · Electronic Components
137174-1
Filter, Band Pass
Part Number137174-1
ManufacturerL3Harris Technologies
AvailabilityAvailable to order — request a quote
Specifications
NSN5915-00-232-3205 (NSN)
Federal Item NameFILTER,BAND PASS
Federal Supply Class5915 — Filters and Networks
Insertion Loss At Reference Freque2.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
Functional Terminal Type And Quant2 CONNECTOR, PLUG INPUT-OUTPUT LOCATION NOT OTHERWISE SPECIFIED
Mounting Facility Type And Quantit2 CLAMP LOCATION NOT OTHERWISE SPECIFIED
Body Length5.937 INCHES NOMINAL
Input Impedance Per Function W Loa75.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
Output Impedance Per Function W So75.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
Frequency Band Width Per Function30.10 MEGAHERTZ BLANK AND 38.10 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
Reference Frequency Per Function34.1 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
Style DesignatorRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
Body Width1.968 INCHES NOMINAL
Inclosure TypeUNINCLOSED
ESD/EMICode A — ESD/EMI sensitive item
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Frequently asked
Is 137174-1 available?
We can source 137174-1 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 137174-1 by L3Harris Technologies obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 137174-1 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 137174-1?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 137174-1?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.