● ISO 9001:2015 · ANSI/ESD S20.20-2021 · ERAI Member · GIDEP · Woman-Owned Small Business 760.724.2800 · 855.RH.HAS.IT · info@rhelectronics.com
Home / Catalog / Vishay Sprague / 1308-0013
Vishay Sprague  · Electronic Components

1308-0013

Resistor, Variable, Nonwire Wound,

Part Number1308-0013
ManufacturerVishay Sprague
AvailabilityAvailable to order — request a quote

Specifications

Federal Item NameRESISTOR,VARIABLE,NONWIRE WOUND,
Federal Supply Class5905 — Resistors
Function Characteristic Per SectioSINGLE SECTION EQUATION
Power Dissipation Rating Per Secti0.7 FREE AIR SINGLE SECTION
Device Design TypeAT 12:00 OCLOCK
Tap Location Tolerance Per Section-10.0 TO 10.0 OHMS SINGLE SECTION
Resistance Tolerance Per Section I-5.0 TO 5.0 SINGLE SECTION
Terminal Type And Quantity4 TURRET
Test Data Document02111-1308-0013 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTU
Fixed Tap Quantity Per Section1 SINGLE SECTION
Tap Location From Ccw Terminal Per2500.0 SINGLE SECTION
Terminal LocationRADIALLY POSITIONED OVER MORE THAN HALF THE CIRCUMFERENCE LOCATION NOT OTHERWISE SPECIFIED
Ambient Temp In Deg Celsius Per Se75.0 SINGLE SECTION
Review your list (0) →
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant

Frequently asked

Is 1308-0013 available?
We can source 1308-0013 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 1308-0013 by Vishay Sprague obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 1308-0013 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 1308-0013?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 1308-0013?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.