General Instrument Corporation · Electronic Components
126-030
Capacitor, Fixed, Mica Dielectric
Part Number126-030
ManufacturerGeneral Instrument Corporation
AvailabilityAvailable to order — request a quote
Specifications
NSN5910-00-883-4717 (NSN)
Federal Item NameCAPACITOR,FIXED,MICA DIELECTRIC
Federal Supply Class5910 — Capacitors
Body StyleW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
Reliability IndicatorNOT ESTABLISHED
MaterialGLASS CASE
Schematic Diagram DesignatorNO COMMON OR GROUNDED ELECTRODE(S)
Nonderated Continuous Voltage Rati500.0 DC SINGLE SECTION
Capacitance Value Per Section1800.000 PICOFARADS SINGLE SECTION
Tolerance Range Per Section-2.00 TO 2.00 PERCENT SINGLE SECTION
Nonderated Operating Temp-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
Body Height0.210 INCHES MAXIMUM
Body Width0.570 INCHES MAXIMUM
Body Length0.790 INCHES MAXIMUM
Vendor Part NumbersD205F182G, 8924416-216, CD20FD182G03
Cancelled NSN5910-01-050-4223 (cancelled)
ProducttraceabilityNo
RohscompliantNA
Blade Diameter30 mm
Product Range-
IscanonicalY
Cutting Depth Max38 mm
Hazardousfalse
RohsphthalatescompliantNA
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Frequently asked
Is 126-030 available?
We can source 126-030 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 126-030 by General Instrument Corporation obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 126-030 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 126-030?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 126-030?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.