● ISO 9001:2015 · ANSI/ESD S20.20-2021 · ERAI Member · GIDEP · Woman-Owned Small Business 760.724.2800 · 855.RH.HAS.IT · info@rhelectronics.com
Drs Advanced Isr, LLC  · Electronic Components

11923-1

Fuse, Indicator Alarm

Part Number11923-1
ManufacturerDrs Advanced Isr, LLC
AvailabilityAvailable to order — request a quote

Specifications

Federal Item NameFUSE,INDICATOR ALARM
Federal Supply Class5920 — Fuses and Lightning Arresters
Surface TreatmentNICKEL TERMINAL
Maximum Voltage Rating In Volts300.0 AC AND 300.0 DC
Overall Width0.150 INCHES MAXIMUM
Overall Length0.844 INCHES MAXIMUM
Continuous Current Rating In Amps0.018
Circuit Over Current InterruptionNORMAL INSTANTANEOUS
Overall Height0.625 INCHES MAXIMUM
Interruption Indicator MethodGRASSHOPPER
MaterialPLASTIC CASE
Body StyleMINIATURE GRASSHOPPER
Vendor Part Numbers264-0598-000
ESD/EMICode A — ESD/EMI sensitive item
Impregnation MaterialVARNISH
Unable To DecodeUNABLE TO DECODE
FSC Application DataEXCEPT ENGINE
Coil Type And Quantity1 FLAT
Terminal Type And Quantity2 ROUND WIRE LEAD ALL TERMINALS
ProducttraceabilityNo
RohscompliantTBA
IscanonicalY
Hazardousfalse
Review your list (0) →
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant

Frequently asked

Is 11923-1 available?
We can source 11923-1 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 11923-1 by Drs Advanced Isr, LLC obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 11923-1 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 11923-1?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 11923-1?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.