Specifications

Federal Item NameSWITCH,THERMOSTATIC
Federal Supply Class5930 — Switches
Body Diameter0.572 INCHES MAXIMUM
Overall Width0.435 INCHES NOMINAL
Operating Temp Rating50.0 CELSIUS MAXIMUM AND -28.0 CELSIUS MINIMUM
Style DesignatorRECTANGULAR
Frequency In Hertz60.0 SINGLE VOLTAGE
Body Length0.215 INCHES NOMINAL
Mounting Facility PatternTWO POSITION IN-LINE
Contact AdjustabilityDEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
Contact Stimulus Rating75.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 85.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 55.00 DEACTUAT
Distance Between Mounting Facility1.680 INCHES MINIMUM AND 1.694 INCHES MAXIMUM
Contact Load Current Rating2.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE
Vendor Part Numbers2681237
Review your list (0) →
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant

Frequently asked

Is 11041-84-6 available?
We can source 11041-84-6 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 11041-84-6 by Sensata Technologies obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 11041-84-6 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 11041-84-6?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 11041-84-6?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.