Fluke Corp. · Electronic Components
106864
Relay, Electromagnetic
Part Number106864
ManufacturerFluke Corp.
AvailabilityAvailable to order — request a quote
Specifications
NSN5945-00-359-6889 (NSN)
Federal Item NameRELAY,ELECTROMAGNETIC
Federal Supply Class5945 — Relays and Solenoids
Overall Length1.812 INCHES MAXIMUM
Terminal Type And Quantity8 PIN ALL FUNCTIONS
Main Contact Maximum Voltage Ratin115.0 AC AND 26.0 DC
Winding Quantity1
Nonpile Up Main Contact Arrangemen2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
Mounting Facility Type And Quantit1 THREADED STUD(S) SINGLE MOUNTING FACILITY
Duty TypeCONTINUOUS
Time Delay0.02 SECONDS MAXIMUM FIXED OPERATE TIME
Coil Quantity1
Thread Class2A SINGLE MOUNTING FACILITY
Overall Height1.375 INCHES MAXIMUM
Vendor Part Numbers20003-84, 100DPDT5A120VAC
Style DesignatorFIVE BEND TYPE
Waveguide Third Leg Length11.218 INCHES NOMINAL
FlexibilityRIGID SINGLE TUBING SEGMENT
Waveguide Sixth Leg Length5.010 INCHES NOMINAL
Waveguide First Leg Length8.788 INCHES NOMINAL
Tubing Wall Construction StyleSEAMLESS SINGLE TUBING SEGMENT
Waveguide Fourth Leg Length16.072 INCHES NOMINAL
Waveguide Fifth Leg Length10.286 INCHES NOMINAL
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Frequently asked
Is 106864 available?
We can source 106864 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 106864 by Fluke Corp. obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 106864 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 106864?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 106864?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.