Brainin-Advance Industries, LLC · Electronic Components
104A
Terminal, Lug
Part Number104A
ManufacturerBrainin-Advance Industries, LLC
AvailabilityAvailable to order — request a quote
Specifications
NSN5940-00-503-6345 (NSN)
Federal Item NameTERMINAL,LUG
Federal Supply Class5940 — Lugs, Terminals, and Terminal Strips
Surface TreatmentTIN MOUNTING FACILITY SINGLE LAYER
MaterialCOPPER CONDUCTOR ACCOMMODATION
Conductor Accommodation TypeCLAMPING TANG EARS SINGLE END
Mounting Slot Width0.156 INCHES
Mounting Tongue Width0.297 INCHES
Maximum Conductor Size Accommodate10 AWG
Mounting Facility Thickness0.032 INCHES
Electrical Insulation FeatureUNINSULATED
Overall Width0.297 INCHES
Basic Shape StyleSOLDER/SOLDERLESS
Mounting Method StyleSLOT
Vendor Part Numbers712170-14, SMC149616-2, RM104ALP
Cancelled NSN5940-00-539-2183 (cancelled)
Mounting Facility Type And Quantit1 FRICTION
Center To Center Distance Between0.750 INCHES
Material Document And ClassificatiQQ-A-250/11,T6 FED SPEC SINGLE MATERIAL RESPONSE BOARD
Board ConstructionSOLID CONSTRUCTION
Board Thickness0.063 INCHES
Nonfeedthru Terminal Type597 SINGLE
Terminal Pattern ArrangementSINGLE ROW
Board Overall Width0.750 INCHES
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Frequently asked
Is 104A available?
We can source 104A even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 104A by Brainin-Advance Industries, LLC obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 104A has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 104A?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 104A?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.