04-0302-2470

Shielding Gasket, Electronic

Part Number04-0302-2470
ManufacturerParker-Hannifin
AvailabilityAvailable to order — request a quote

Specifications

Federal Item NameSHIELDING GASKET,ELECTRONIC
Federal Supply Class5999 — Miscellaneous Electrical Components
Material Document And ClassificatiAMS 4182 ASSN STD SINGLE MATERIAL RESPONSE EMI/RFI CONDUCTOR
Overall Length1.094 INCHES NOMINAL
Aperture Diameter0.750 INCHES MINIMUM AND 0.796 INCHES MAXIMUM
Overall Width1.094 INCHES NOMINAL
MaterialRUBBER SILICONE CLASS Q ENVIRONMENTAL SEAL
Style DesignatorNON-CIRCULAR
Outside Corner Radius0.230 INCHES MINIMUM AND 0.364 INCHES MAXIMUM
Environmental Protection MaterialTHROUGHOUT RF SHIELDING GASKET
Hole Diameter0.115 INCHES MINIMUM AND 0.182 INCHES MAXIMUM
Outside Edge To Bolt Hole Center D0.141 INCHES NOMINAL
Cross Sectional Shape StyleEMI
Vendor Part Numbers42-470, 42-61112, 579R366H03
ESD/EMICode A — ESD/EMI sensitive item
Review your list (0) →
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant

Frequently asked

Is 04-0302-2470 available?
We can source 04-0302-2470 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 04-0302-2470 by Parker-Hannifin obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 04-0302-2470 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 04-0302-2470?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 04-0302-2470?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.