Keysight Technologies Inc. · Electronic Components
0140-0003
Capacitor, Fixed, Mica Dielectric
Part Number0140-0003
ManufacturerKeysight Technologies Inc.
AvailabilityAvailable to order — request a quote
Specifications
NSN5910-00-082-7422 (NSN)
Federal Item NameCAPACITOR,FIXED,MICA DIELECTRIC
Federal Supply Class5910 — Capacitors
Temp Coefficient Of Capacitance Ra-20.0 TO 100.0 SINGLE SECTION
Reliability IndicatorNOT ESTABLISHED
Insulation Resistance At Maximum O20000.0 MEGOHMS
MaterialPLASTIC CASE
Terminal Surface TreatmentSOLDER
Quality Factor At Reference Temp1100.0000
Insulation Resistance At Reference100000.0 MEGOHMS
Tolerance Range Per Section-10.00 TO 10.00 PERCENT SINGLE SECTION
Body StyleW/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES
Schematic Diagram DesignatorNO COMMON OR GROUNDED ELECTRODE(S)
Terminal Length1.125 INCHES MINIMUM
Dc Leakage At Reference Temp1.000 MICROAMPERES
Capacitive Electrode MaterialTANTALUM
Dissipation Factor At Reference Te6.0000
Terminal Type And Quantity2 UNINSULATED WIRE LEAD
Nonderated Continuous Voltage Rati20.0 DC SINGLE SECTION
Vendor Part Numbers110602-012, 110602-160
Cancelled NSN5910-00-008-4436 (cancelled)
RH Electronics, Inc. — independent stocking distributor since 1982.
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Every shipment inspected on receipt · ISO 9001:2015 · ANSI/ESD S20.20 · ERAI member since 1998 · GIDEP participant
Frequently asked
Is 0140-0003 available?
We can source 0140-0003 even if it isn't in our active stock list. As an independent distributor we reach inventory outside the franchise channel — including hard-to-find and obsolete parts. Send us a quote request.
Is 0140-0003 by Keysight Technologies Inc. obsolete or end-of-life?
We specialize in obsolete, end-of-life, and discontinued components. If 0140-0003 has been discontinued, we can often source remaining stock or qualified alternates. Contact us with your quantity and target date.
How does RH Electronics verify parts like 0140-0003?
Every incoming shipment is inspected under our ISO 9001:2015 quality system — documentation, markings, and construction checked against known-good references. For deeper analysis, we direct work through accredited independent labs. We've been an ERAI member since 1998 and a GIDEP participant.
Can you find a cross-reference or alternate for 0140-0003?
Yes. Our team reads part numbers the way they were designed — decoding family, speed, temperature grade, package, and reliability level — to identify acceptable alternates when the exact part isn't available. Submit a quote request and we'll advise.